Item Name | Resistor Fixed Wire Wound Induct |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-780-7488 (007807488) |
NCB Code | USA (00) |
Manufacturer | Military Specifications, Clarostat Sensors And Controls, Alliant Techsystems Operations Llc, Rockwell Collins Aerospace, Nautel Limited, Vishay Dale Electronics Inc, Joint Army-Navy Specifications |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
MILR26 | military specifications | resistor fixed wire wound induct | RFQ |
RW67G281 | military specifications | resistor fixed wire wound induct | RFQ |
VC5E270 | clarostat sensors and controls | resistor fixed wire wound induct | RFQ |
2604431-2 | alliant techsystems operations llc | resistor fixed wire wound induct | RFQ |
747-5449-00 | rockwell collins aerospace | resistor fixed wire wound induct | RFQ |
RW57G271 | military specifications | resistor fixed wire wound induct | RFQ |
RW67V271 | military specifications | resistor fixed wire wound induct | RFQ |
RQ31 | nautel limited | resistor fixed wire wound induct | RFQ |
MIL-R-26/4 | military specifications | resistor fixed wire wound induct | RFQ |
CW5-271J | vishay dale electronics inc | resistor fixed wire wound induct | RFQ |
RW57G271 | joint army-navy specifications | resistor fixed wire wound induct | RFQ |
RW67G271 | military specifications | resistor fixed wire wound induct | RFQ |
747-5449-000 | rockwell collins aerospace | resistor fixed wire wound induct | RFQ |
MIL-PRF-26/4 | military specifications | resistor fixed wire wound induct | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 350.0 |
ABPM | BODY DIAMETER | 0.313 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.000 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 6.500 FREE AIR |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CSCF | TERMINAL TYPE | WIRE LEAD |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -260.0 TO 260.0 |
AAPP | ELECTRICAL RESISTANCE | 270.000 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 350.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MILR26/4 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING |
Relevant Components for NSN - 5905-00-780-7488, 5905007807488 | ||||
5920-01-337-7645 (5920013377645) | 5995-01-688-0358 (5995016880358) | 5935-01-132-7705 (5935011327705) | 5910-00-152-4145 (5910001524145) | |
5945-01-363-9722 (5945013639722) | 5975-01-032-9067 (5975010329067) | 5998-01-433-6008 (5998014336008) | 5970-01-298-0394 (5970012980394) | |
5998-01-674-4887 (5998016744887) | 5935-01-294-4644 (5935012944644) | 5975-01-216-8288 (5975012168288) | 5915-00-412-1691 (5915004121691) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote