Item Name | Resistor Fixed Wire Wound Induct |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 01-049-2089 (010492089) |
NCB Code | USA (01) |
Manufacturer | Military Specifications, Raytheon Company, General Electric Company, Carleton Life Support Technologies, Bae Systems Inc, Boeing Company The, Vishay Dale Electronics Inc, Tel Labs Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
MILR39007-8 | military specifications | resistor fixed wire wound induct | RFQ |
538216-1426 | raytheon company | resistor fixed wire wound induct | RFQ |
J165P2670F | general electric company | resistor fixed wire wound induct | RFQ |
1623410-426 | carleton life support technologies | resistor fixed wire wound induct | RFQ |
RWR80S2671FS | military specifications | resistor fixed wire wound induct | RFQ |
230510-572 | bae systems inc | resistor fixed wire wound induct | RFQ |
443-0955-427 | boeing company the | resistor fixed wire wound induct | RFQ |
RWR80S2671FP | military specifications | resistor fixed wire wound induct | RFQ |
RWR80S2671FR | military specifications | resistor fixed wire wound induct | RFQ |
G3X063B26700F | vishay dale electronics inc | resistor fixed wire wound induct | RFQ |
RWR80S2671FM | military specifications | resistor fixed wire wound induct | RFQ |
W80S2671FSJ | military specifications | resistor fixed wire wound induct | RFQ |
EL1A-2-7K-1W-1 | tel labs inc | resistor fixed wire wound induct | RFQ |
MIL-PRF-39007/8 | military specifications | resistor fixed wire wound induct | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -20.0 TO 20.0 |
AAPP | ELECTRICAL RESISTANCE | 2.670 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 275.0 |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.094 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.406 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 2.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CSCF | TERMINAL TYPE | WIRE LEAD |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39007 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39007/8 GOVERNMENT SPECIFICATION |
Relevant Components for NSN - 5905-01-049-2089, 5905010492089 | ||||
5920-01-337-7645 (5920013377645) | 5995-01-688-0358 (5995016880358) | 5935-01-132-7705 (5935011327705) | 5910-00-152-4145 (5910001524145) | |
5945-01-363-9722 (5945013639722) | 5975-01-032-9067 (5975010329067) | 5998-01-433-6008 (5998014336008) | 5970-01-298-0394 (5970012980394) | |
5998-01-674-4887 (5998016744887) | 5935-01-294-4644 (5935012944644) | 5975-01-216-8288 (5975012168288) | 5915-00-412-1691 (5915004121691) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote