Item Name | Filter Radio Frequency Interfere |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5915 Filters and Networks |
National Item Identification Number (NIIN) | 00-351-0374 (003510374) |
NCB Code | USA (00) |
Manufacturer | Spectrum Control Inc, The Captor Corporation, Trane Co The, Keco Industries Inc, Genisco Filter Corp, Drs Environmental Systems Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
GF8865-2 | spectrum control inc | filter radio frequency interfere | RFQ |
A1238 | the captor corporation | filter radio frequency interfere | RFQ |
B2850-3521 | trane co the | filter radio frequency interfere | RFQ |
83720 | keco industries inc | filter radio frequency interfere | RFQ |
GF8865-2 | genisco filter corp | filter radio frequency interfere | RFQ |
83720 | drs environmental systems inc | filter radio frequency interfere | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 75.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 75.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 75.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 UNTHREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 SOLDER STUD GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 SOLDER STUD INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 SOLDER STUD OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQRG | BODY MATERIAL | METAL |
Relevant Components for NSN - 5915-00-351-0374, 5915003510374 | ||||
5920-01-337-7645 (5920013377645) | 5995-01-688-0358 (5995016880358) | 5935-01-132-7705 (5935011327705) | 5910-00-152-4145 (5910001524145) | |
5945-01-363-9722 (5945013639722) | 5975-01-032-9067 (5975010329067) | 5998-01-433-6008 (5998014336008) | 5970-01-298-0394 (5970012980394) | |
5998-01-674-4887 (5998016744887) | 5935-01-294-4644 (5935012944644) | 5975-01-216-8288 (5975012168288) | 5915-00-412-1691 (5915004121691) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote