Item Name | Switch Pressure |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
National Item Identification Number (NIIN) | 00-845-9420 (008459420) |
NCB Code | USA (00) |
Manufacturer | Mercoid Corp, Dwyer Instruments Inc |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.125 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 5.750 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AXGY | MOUNTING METHOD | INLET CONNECTION |
CMLP | THREAD QUANTITY PER INCH | 18 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYM | CONTACT ADJUSTMENT RANGE | +0.00/+300.00 ACTUATION POINT POUNDS PER SQUARE INCH |
CTYX | CONTACT STIMULUS RATING | 6.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL THIRD VOLTAGE |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
Relevant Components for NSN - 5930-00-845-9420, 5930008459420 | ||||
5920-01-337-7645 (5920013377645) | 5995-01-688-0358 (5995016880358) | 5935-01-132-7705 (5935011327705) | 5910-00-152-4145 (5910001524145) | |
5945-01-363-9722 (5945013639722) | 5975-01-032-9067 (5975010329067) | 5998-01-433-6008 (5998014336008) | 5970-01-298-0394 (5970012980394) | |
5998-01-674-4887 (5998016744887) | 5935-01-294-4644 (5935012944644) | 5975-01-216-8288 (5975012168288) | 5915-00-412-1691 (5915004121691) | |