Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 00-532-1571 (005321571) |
NCB Code | USA (00) |
Manufacturer | Telephone Systems Communications, Allied Controls Inc, Capstan Ag Systems Inc, American Zettler, Se Relays Llc, Cp Clare Corp, Sypris Electronics Llc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
A503T003-105 | telephone systems communications | relay electromagnetic | RFQ |
T154-4C-48VDC | allied controls inc | relay electromagnetic | RFQ |
703500-106 | capstan ag systems inc | relay electromagnetic | RFQ |
AZ421-56-1 | american zettler | relay electromagnetic | RFQ |
603500-106 | capstan ag systems inc | relay electromagnetic | RFQ |
T154X-212 | allied controls inc | relay electromagnetic | RFQ |
W67C SX-9 | se relays llc | relay electromagnetic | RFQ |
AZ421-56-1H | american zettler | relay electromagnetic | RFQ |
T154-4C48V | allied controls inc | relay electromagnetic | RFQ |
VPCAB47 | cp clare corp | relay electromagnetic | RFQ |
197610 | sypris electronics llc | relay electromagnetic | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.310 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.120 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 2.5 KILOHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 1.100 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 40 SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.008 SECONDS NOMINAL FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.014 SECONDS NOMINAL FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 48.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 29.0 DC |
CWJB | ENERGIZING ELEMENT POWER RATING | 1.0 WATTS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
Relevant Components for NSN - 5945-00-532-1571, 5945005321571 | ||||
5920-01-337-7645 (5920013377645) | 5995-01-688-0358 (5995016880358) | 5935-01-132-7705 (5935011327705) | 5910-00-152-4145 (5910001524145) | |
5945-01-363-9722 (5945013639722) | 5975-01-032-9067 (5975010329067) | 5998-01-433-6008 (5998014336008) | 5970-01-298-0394 (5970012980394) | |