Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 00-794-6619 (007946619) |
NCB Code | USA (00) |
Manufacturer | Airpax Corp, Westinghouse Electric Corp, Tyco Electronics Corporation, Northrop Grumman Systems Corporation |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
8247-13HS | airpax corp | relay electromagnetic | RFQ |
575R279H01 | westinghouse electric corp | relay electromagnetic | RFQ |
8247-13HS | tyco electronics corporation | relay electromagnetic | RFQ |
575R279H01 | northrop grumman systems corporation | relay electromagnetic | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 3.620 INCHES NOMINAL |
AKDX | WINDING QUANTITY | 2 |
APNA | WINDING DC RESISTANCE RATING | 75.0 OHMS NOMINAL ALL WINDINGS |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 27.5 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 12 PIN ALL FUNCTIONS |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 4.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.000 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
APCN | COIL QUANTITY | 2 |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.035 SECONDS MAXIMUM FIXED OPERATE TIME |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
Relevant Components for NSN - 5945-00-794-6619, 5945007946619 | ||||
5920-01-337-7645 (5920013377645) | 5995-01-688-0358 (5995016880358) | 5935-01-132-7705 (5935011327705) | 5910-00-152-4145 (5910001524145) | |
5945-01-363-9722 (5945013639722) | 5975-01-032-9067 (5975010329067) | 5998-01-433-6008 (5998014336008) | 5970-01-298-0394 (5970012980394) | |
5998-01-674-4887 (5998016744887) | 5935-01-294-4644 (5935012944644) | 5975-01-216-8288 (5975012168288) | 5915-00-412-1691 (5915004121691) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote