Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 01-200-5915 (012005915) |
NCB Code | USA (01) |
Manufacturer | Air Dry Co Of America Llc, Cooper Wiring Devices Inc, G General Electro Components Inc, Tyco Electronics Corporation, Johnson Controls Inc, Potter And Brumfield Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
6223-75 | air dry co of america llc | relay electromagnetic | RFQ |
30E2CA120 | cooper wiring devices inc | relay electromagnetic | RFQ |
CRH-5-3A120 | g general electro components inc | relay electromagnetic | RFQ |
KUP14A11-120V | tyco electronics corporation | relay electromagnetic | RFQ |
024-20089A | johnson controls inc | relay electromagnetic | RFQ |
KUP14A11120 | potter and brumfield inc | relay electromagnetic | RFQ |
KUP14A11120 | tyco electronics corporation | relay electromagnetic | RFQ |
KUP14A11 | tyco electronics corporation | relay electromagnetic | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.531 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 2.093 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.406 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 50.0 MINIMUM AND 60.0 MAXIMUM |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 1.7 KILOHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 4.505 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 24.0 MILLIAMPERES AC SINGLE WINDING |
CRXH | TIME DELAY | 0.01 SECONDS NOMINAL FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.015 SECONDS NOMINAL FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 28.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 11 TAB,SOLDER LUG ALL FUNCTIONS |
Relevant Components for NSN - 5945-01-200-5915, 5945012005915 | ||||
5920-01-337-7645 (5920013377645) | 5995-01-688-0358 (5995016880358) | 5935-01-132-7705 (5935011327705) | 5910-00-152-4145 (5910001524145) | |
5945-01-363-9722 (5945013639722) | 5975-01-032-9067 (5975010329067) | 5998-01-433-6008 (5998014336008) | 5970-01-298-0394 (5970012980394) | |
5998-01-674-4887 (5998016744887) | 5935-01-294-4644 (5935012944644) | 5975-01-216-8288 (5975012168288) | 5915-00-412-1691 (5915004121691) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote