Item Name | Power Supply |
Federal Supply Group (FSG) | Electric Wire and Power and Distribution Equipment |
Federal Supply Class (FSC) | 6130 Converters Electrical Non Rotating |
National Item Identification Number (NIIN) | 01-057-3515 (010573515) |
NCB Code | USA (01) |
Manufacturer | Oakleaf Inc, Taiyo Yuden Usa Inc, Mcdonnell Douglas Corp, Hamilton Sundstrand Corporation |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
QTD1 | oakleaf inc | power supply | RFQ |
3MA5-15 | oakleaf inc | power supply | RFQ |
XPT60S | taiyo yuden usa inc | power supply | RFQ |
B54EG052-4 | mcdonnell douglas corp | power supply | RFQ |
GS9981-15 | hamilton sundstrand corporation | power supply | RFQ |
3MA5-15S | oakleaf inc | power supply | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 11.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.880 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.880 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -15.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/40.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | -1.3 DC AMPERES MINIMUM 3RD POWER OUTPUT AND-1.5 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.3 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 1.5 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 6.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
Relevant Components for NSN - 6130-01-057-3515, 6130010573515 | ||||
6145-00-526-3006 (6145005263006) | 6150-01-425-2499 (6150014252499) | 6115-00-255-3106 (6115002553106) | 6150-01-652-2134 (6150016522134) | |
6105-00-933-8317 (6105009338317) | 6150-01-544-1613 (6150015441613) | 6145-01-531-6748 (6145015316748) | 6150-21-913-4578 (6150219134578) | |
6110-01-095-2965 (6110010952965) | 6130-01-645-6254 (6130016456254) | 6105-01-188-0245 (6105011880245) | 6105-01-302-5336 (6105013025336) | |