Item Name | Power Supply |
Federal Supply Group (FSG) | Electric Wire and Power and Distribution Equipment |
Federal Supply Class (FSC) | 6130 Converters Electrical Non Rotating |
National Item Identification Number (NIIN) | 01-379-5494 (013795494) |
NCB Code | USA (01) |
Manufacturer | Egs Electrical Corporation, Sola Electric A Unit Of General Signal Corp, Emerson Electric Gmbh And Co |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
SLT-12-31010-12T | egs electrical corporation | power supply | RFQ |
SLT-12-31010-12 | sola electric a unit of general signal corp | power supply | RFQ |
SLT-12-31010-12T | emerson electric gmbh and co | power supply | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 100.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 240.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS MINIMUM 3RD POWER OUTPUT AND-15.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.8 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 1.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.8 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 1.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
ABHP | OVERALL LENGTH | 10.250 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.000 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SCREW SINGLE POWER OUTPUT |
Relevant Components for NSN - 6130-01-379-5494, 6130013795494 | ||||
6145-00-526-3006 (6145005263006) | 6150-01-425-2499 (6150014252499) | 6115-00-255-3106 (6115002553106) | 6150-01-652-2134 (6150016522134) | |
6105-00-933-8317 (6105009338317) | 6150-01-544-1613 (6150015441613) | 6145-01-531-6748 (6145015316748) | 6150-21-913-4578 (6150219134578) | |
6110-01-095-2965 (6110010952965) | 6130-01-645-6254 (6130016456254) | 6105-01-188-0245 (6105011880245) | 6105-01-302-5336 (6105013025336) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote