Are you in search of Transformer Power components by Altec Lansing Corp? If so, connect with the experts at Buy National Stock Numbers. With countless new, used, obsolete, and hard-to-find items in our catalogs, customers can easily meet rigid time constraints and inflexible budget parameters. We also make it a priority to maintain a diverse inventory of items so customers from a wide range of industry verticals can source from us. On this page, you can submit a quote request form for part number 7045 with NSN 5950008655017 to receive a customized solution within 15 minutes or less of submission.
Note : We Will Not Share Your Information To Any Third Parties.
Buy National Stock Numbers should be your go-to choice for part sourcing, as we are one of the only major distributors that operates with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation, in addition to adhering to a strict No China Sourcing policy. For your ease of search, our catalogs feature items with the CAGE Code 05614 and FSC 5950 Coils and Transformers. Get started with a competitive quote for NSN 5950-00-865-5017, a component manufactured by Altec Lansing Corp, and see how we can serve as your strategic sourcing solution. For questions about our other offered services, contact us via phone or email!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-865-5017 Item PartTypeName: TRANSFORMER,POWER | 5950 | 008655017 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
7045 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 9.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.612 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 10.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 7.500 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
CMLP | THREAD QUANTITY PER INCH | 18 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.312 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 4.16 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 13.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 13.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 26.60 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.60 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | PRIMARY WINDING IS TAPPED W/ 30 TERMINALS TO PROVIDED VARIOUS SECONDARY VOLTAGE IN 1 OR 2 V STEPS |
TTQY | TERMINAL TYPE AND QUANTITY | 43 STANDOFF,SOLDER LUG |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAU | BODY HEIGHT | 4.750 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 8 SINGLE GROUP |