Are you in search of Adapter Waveguide components by Microlab Fxr? If so, connect with the experts at Buy National Stock Numbers. With countless new, used, obsolete, and hard-to-find items in our catalogs, customers can easily meet rigid time constraints and inflexible budget parameters. We also make it a priority to maintain a diverse inventory of items so customers from a wide range of industry verticals can source from us. On this page, you can submit a quote request form for part number 601-A07 with NSN 5985000502526 to receive a customized solution within 15 minutes or less of submission.
Note : We Will Not Share Your Information To Any Third Parties.
Buy National Stock Numbers should be your go-to choice for part sourcing, as we are one of the only major distributors that operates with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation, in addition to adhering to a strict No China Sourcing policy. For your ease of search, our catalogs feature items with the CAGE Code 00929 and FSC 5985 Antennas Waveguides and Related Equipment. Get started with a competitive quote for NSN 5985-00-050-2526, a component manufactured by Microlab Fxr, and see how we can serve as your strategic sourcing solution. For questions about our other offered services, contact us via phone or email!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-00-050-2526 Item PartTypeName: ADAPTER,WAVEGUIDE | 5985 | 000502526 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
E6761 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 1 |
AHSX | FLANGE INSIDE WIDTH | 2.002 INCHES MINIMUM AND 2.005 INCHES MAXIMUM SINGLE FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 1.002 INCHES MINIMUM AND 1.005 INCHES MAXIMUM SINGLE FLANGE |
AHTC | FLANGE OUTSIDE DIAMETER | 3.610 INCHES MINIMUM AND 3.640 INCHES MAXIMUM SINGLE FLANGE |
AHTD | FLANGE DEPTH | 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM SINGLE FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.199 INCHES MINIMUM AND 0.203 INCHES MAXIMUM SINGLE FLANGE ALL CONNECTION FACILITIES |
AHUC | COAXIAL CONNECTOR SERIES DESIGNATION | N |
AHUD | CONNECTOR END DESIGN | FEMALE |
BBPN | ADAPTER LENGTH | 2.000 INCHES NOMINAL |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.876 INCHES MINIMUM AND 1.877 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.867 INCHES MINIMUM AND 0.877 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE SINGLE FLANGE SINGLE CONNECTION FACILITY |
CSRQ | ADAPTER DIAMETER | 3.625 INCHES NOMINAL |
CTCJ | FLANGE STYLE | COVER TYPE SINGLE FLANGE |
CWBQ | ADAPTER OVERALL HEIGHT | 2.812 INCHES NOMINAL |
MATT | MATERIAL | COPPER ALLOY SINGLE TUBING SEGMENT AND FLANGE |
STYL | STYLE DESIGNATOR | WAVEGUIDE TO COAXIAL |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote