Are you in search of Relay Electromagnet components by Military Specifications? If so, connect with the experts at Buy National Stock Numbers. With countless new, used, obsolete, and hard-to-find items in our catalogs, customers can easily meet rigid time constraints and inflexible budget parameters. We also make it a priority to maintain a diverse inventory of items so customers from a wide range of industry verticals can source from us. On this page, you can submit a quote request form for part number MIL-PRF-6106 with NSN 5945013448943 to receive a customized solution within 15 minutes or less of submission.
Note : We Will Not Share Your Information To Any Third Parties.
Buy National Stock Numbers should be your go-to choice for part sourcing, as we are one of the only major distributors that operates with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation, in addition to adhering to a strict No China Sourcing policy. For your ease of search, our catalogs feature items with the CAGE Code 81349 and FSC 5945 Relays and Solenoids. Get started with a competitive quote for NSN 5945-01-344-8943, a component manufactured by Military Specifications, and see how we can serve as your strategic sourcing solution. For questions about our other offered services, contact us via phone or email!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-344-8943 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 013448943 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
MS27751-19 | 5 | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 3.130 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.440 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CBME | CUBIC MEASURE | 0.707 CUBIC INCHES |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE MOUNTING FACILITY |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC LAMP LOAD AND 10.0 AMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 60.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
TTQY | TERMINAL TYPE AND QUANTITY | 13 THREADED STUD ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS27751 GOVERNMENT STANDARD |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 2.500 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.990 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.168 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.175 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 160.0 MILLIAMPERES DC SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES DC INDUCTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 40.0 AMPERES AC MOTOR LOAD AND 20.0 AMPERES DC MOTOR LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 PROBE AC LAMP LOAD AND 1.0 PROBE DC LAMP LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 PROBE AC INDUCTIVE LOAD AND 3.0 PROBE DC INDUCTIVE LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 PROBE AC RESISTIVE LOAD AND 3.0 PROBE DC RESISTIVE LOAD |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNA | WINDING DC RESISTANCE RATING | 200.0 OHMS NOMINAL SINGLE WINDING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |